RGT-MT18 - Reactive power regulator 18 levels +TCR with RS485 ModBus

Only 2 left
SKU: RGT-MT18
Common price 300,00 kr incl. VAT

Online payment by card - after the order is completed you will be redirected to the payment portal, the confirmation of the payment will be sent to your e-mail

Postförskott - betaling enligt betalningsföreskriften du till chauffeur från transportföretaget

Överföring - you will receive a proforma invoice by e-mail no later than the next working day, where you will find the account number that you entered when paying.

On invoice - this payment variant has partners who have entered into a framework agreement with our company.

If you want to use the last 2 methods, call our manager and he will give you instructions on how to get an invoice with or without VAT.

The electrical appliances we supply meet high quality standards, have a 24-month warranty and meet all EU requirements.

In the event of a complaint, no fee is charged for the return of goods.

18 steps + TCR power factor regulator for symmetric/asymmetric networks with 5-inch touch screen and RS-485 (TENSE)

Relays for controlling reactive power are designed to reduce reactive power (inductive and capacitive) that is not used by the load and is drawn from the grid. When inductive power is drawn from the grid, it intervenes by removing a capacitor with an appropriate value. If capacitive power is drawn from the grid, it intervenes by taking a shunt inductor with an appropriate value. In this way, it attempts to reduce the system's inductive/active and capacitive/active speeds. It is designed to provide more reasonable compensation in unbalanced inductive and capacitive systems with the RGT-MT18 TCR step.

  • Generator input and generator compensation

  • Voltage, harmonic current/voltage, inductive and capacitive alarm output

  • Hit, discharge, and settling times can be adjusted

  • Remote communication with RS485 (RS485 ModBus RTU)

  • Single-phase, two-phase, and three-phase capacitors and shunt reactors can be connected

  • Harmonic voltage and current can be observed up to the 61st harmonic

  • Total energy (import/export) can be monitored

  • THD-V and THD-I values for each phase can be observed

  • Create power analysis (20 samples 9999 min.) - for capacitor selection

  • Temperature alarm output

  • Demand registration (active and reactive and apparent power and current demand)

  • Minimum, maximum, and average current and voltage values for each phase can be monitored

  • Current date and time